Common Problem
Your current position: Home > News > Common Problem
Equipment line (AWM) UL1015 specifications
Source: Xinya wire&cable Co.,LtdPopularity: 1218Time: 2017-02-21【SML】
UL1015
A. PVC insulated electronic wire
B. Conductor: 30AWG-2000kcmil (10AWG = 10kcmil)
C. Burning test: can be tested by horizontal
combustion
D. Rating: 80 ℃, 90 ℃, 105 ℃; 600V ac, 750V dc
E. Insulator: PVC, the thickness of the table
below
Specification
Average
minimum thickness
Minimum
thickness of any point
30AWG-9AWG
0.76mm
0.68mm
8AWG-7AWG
1.15mm
1.02mm
6AWG-2AWG
1.52mm
1.37mm